The procedure of FCVB implantation. [23] (a) Pars plana vitrectomy was performed. (b) A scleral cut was made, and the folded FCVB was placed in the vitreous cavity. (c) SO was injected into the capsule through the valve. (d) The valve was fixed onto the sclera.
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 00:12, May 3, 2023 | 706 × 489 (55 KB) | Hashem.AbuSerhan (talk | contribs) | The steps of foldable capsular vitreous body implantation, drawn. |